Feature:
4 string 16.8V 40A lithium battery protection board (comes with recovery function-AUTO Recovery)
Scope: Nominal voltage of 3.6V, 3.7V lithium battery (including 18650,26650, polymer lithium battery)
Product Size: 45 * 55 * 3.4mm (Standard Edition / Enhanced), 46 * 60 * 3.4mm (balanced version)
Product weight: 9.3g (standard / enhanced version), 10.3g (balanced version)
Charging voltage: 16.8V - 18.1V
Continuous discharge current (upper limit): 40A (if the cooling environment is not good, please reduce the load current use)
Continuous charge current (upper limit): 20A
Equalization version: suitable for starting current below 80A, power 135W below the drill.
Project | Min. | Typ. | Max. | Units |
Consuming current | 12 | 18 | 24 | uA |
Overcharged protection voltage | 4.2 | 4.25 | 4.3 | V |
Balanced starting voltage | 4.17 | 4.2 | 4.23 | V |
Equilibrium current | 95 | 100 | 105 | mA |
Balanced heating power | 1.56 | 1.72 | 1.91 | W |
Overcharge recovery voltage | 4.1 | 4.15 | 4.2 | V |
Over-discharge protection voltage | 2.4 | 2.5 | 2.6 | V |
Overvoltage protection after over-discharge protection | 2.8 | 3 | 3.2 | V |
Overvoltage protection after over-discharge protection | 3.2 | 3.5 | 3.8 | V |
Over-discharge recovery voltage | 2.9 | 3.2 | 3.3 | V |
Conduction internal resistance | 2.5 | 3 | 3.5 | mQ |
Overcurrent protection current C | 70 | 80 | 90 | A |
Overcurrent delay time | 100 | 150 | 200 | ms |
Continuous operating current | 0 | 40 | 40 | A |
Continuous output power | 0 | 672 | 672 | W |
Ambient temperature | -40 | 25 | 85 | °C |
>td >Unable to charge>td >Repair welding>td >Remove the component and re-weld
Troubleshooting: | ||
Fault phenomenon | Fault check and cause | |
Measuring the voltage of 4 groups of batteries. when one of the battery voltages exceeds 4.25V, the protection board will activate overcharge protection. | Pair the battery pack well, do not mix the good battery and the bad battery. | |
Unable to discharge | Measuring the voltage of 4 groups of batteries. when one of the battery voltages is lower than 2.7V, the protection board will activate the over-discharge protection. | Pair the battery pack well, do not mix the good battery and the bad battery. |
Charging/discharging failure | OV, 4.2V, S.4V, 12.6V, 16.8V miswired | Rewire or replace the new board (human failure, no warranty) |
Overcharge/overdischarge failure | OV, 4.2V, 8.4V, 12.6V, 16.8V miswired | Rewire or replace the new board (human failure, no warranty) |
Discharge protection | Check that the battery pack has sufficient discharge capability and check that the load's starting current exceeds the overcurrent protection current of the protection board. | Replace the battery pack with a higher discharge capacity, or a protective plate with a larger current (super working range) |
Component soldering | and the PCB pad. | |
Component welding | component. | |
Electrostatic breakdown A | In the unpowered state, measure the G, D, and S poles of the MOSFET. If the forward and reverse resistances of any two pins are 0Q, it indicates that it has broken down. | Remove the replacement MOS tube |
Electrostatic breakdown B | Remove the MOS tube and measure the resistance of the G and D, G and S poles of the MOS tube. If there is a resistance indicating that it has broken down, the resistance should be infinite. | Remove the replacement MOS tube |
Package includes:
1 x Battery Protection Board