Grove - Multichannel Gas Sensor V2 has 4 measuring units, each of them is sensitive to various kinds of gases, which means you are able to get four sets of data at the same time. And different sorts of gases can also be judged by these four sets of data. The gas sensor used in this module is based on MEMS technology and has the advantage of being in a small size with considerable measurement stability and is more suitable for qualitative than quantitative measurement.

Features

  • Four fully independent sensor elements on one package.
  • The ability to detect a variety of gases, besides Carbon monoxide (CO), Nitrogen dioxide (NO2), Ethyl alcohol(C2H5CH), Volatile Organic Compounds (VOC) and etc.
  • Qualitative detecting, rather than quantitative.
  • Compact size for easy deployment.

Specification

ItemValue
MCUSTM32F030
InterfaceGrove I2C
I2C address0x55
Output voltage3.3V~5V
SensorsGM-102B; GM-302B; GM-502B; GM-702B

GM-102B

Type of productGM-102B
V0(V)2.5-4.5
V0-VS(V)≥1.0
LoadAdjustable
Response time(tres,S)≤30
Recovery Time(trec,S)≤60
Heating resistance(RH,Ω)80±20
Operating Voltage(V)VH=2.0±0.1 AC or DC VC=5.0±0.1DC

GM-302B

Type of productGM-302B
Standard packageCeramic package
Concentration1~500ppm
Standard circuit conditions Loop voltageVC≤24V DC
Heating VoltageVH2.5V±0.1V AC or DC
Load ResistanceRLAdjustable
Gas sensor characteristics under standard test conditionsHeating resistanceRH60~100Ω(Room Temperature)
Heating power consumptionPH≤50mW
Sensitive body resistanceRS1KΩ~30KΩ(in 50ppm Ethanol )
SensitivitySRs(in air)/Rs(in 50ppm Ethanol )≥3.0
Concentration slopeα≤0.9(R200ppm/R50ppm Ethanol )
Standard test conditionsTemperature/Humidity20℃±2℃;55%±5%RH
Standard test circuitVH:2.5V±0.1V; VC:5.0V±0.1V
Preheat timeLess than 48hrs

GM-502B

Type of productGM-502B
Standard packageCeramic package
Concentration1~500ppm
Standard circuit conditions Loop voltageVC≤24V DC
Heating VoltageVH2.5V±0.1V AC or DC
Load ResistanceRLAdjustable
Gas sensor characteristics under standard test conditionsHeating resistanceRH80Ω ± 20Ω(Room temperature)
Heating power consumptionPH≤50mW
Sensitive body resistanceRS1KΩ~30KΩ (in 50ppm Ethanol)
SensitivitySR0 (in air) / Rs (in 50ppm Ethanol) ≥3.0
Concentration slopeα≤0.9 (R200ppm / R50ppm Ethanol)
Standard test conditions Temperature / Humidity20℃ ± 2℃;55% ± 5%RH
Standard test circuit VH:2.5V ± 0.1V; VC:5.0V ± 0.1V

GM-702B

Type of productGM-702B
Standard packageCeramic package
Concentration5~5000ppm(CO)
Standard circuit conditions Loop voltageVC≤24V DC
Heating VoltageVH2.5V±0.1V AC or DC(High Temperature) 0.5V±0.1V AC or DC(Low Temperature)
Load ResistanceRL60s±1s(H. T);90s±1s(L. T)
Gas sensor characteristics under standard test conditionsHeating resistanceRHAdjustable
Heating power consumptionPH80Ω±20Ω(Room temperature)
Sensitive body resistanceRS≤50mW
SensitivityS1KΩ~30KΩ(in 150ppmCO)
Concentration slopeαR0(in air)/Rs(in 150ppmCO)≥3
Standard test conditions Temperature / Humidity20℃±2℃;55%±5%RH
Standard test circuitVH: 2.5V±0.1V(H. T) 0.5V±0.1V(L. T) VC : 5.0V±0.1V

Sample test outcomes

result outcome

Characteristic descriptions

pir

Rs in the figure represents the resistance value of the sensorin different concentrations of gas; R0 represents the resistance value of the sensor in clean air. All tests in the picture are completed under standard test conditions. Yellow line is Toluene, blue line is Ethanol, red line is Acetone and purple line is Formaldehyde, which is the same as the ones in charts below.

pir

The output voltage in Chart 3 is the voltage across the load resistance (RL) of the sensor in series. The test in the figure is completed under standard test conditions, with a test gas of 50 ppm ethanol. The output voltage in Chart 4 is the voltage across the load resistance (RL) of the sensor in series. All tests in the figure are completed under standard test conditions.

pir

Rs in Chart 5 represents the resistance value of the sensorin different concentrations of gas; R0 represents the resistance value of the sensor in clean air. All tests in the picture are completed under standard test conditions. Yellow line is Toluene, blue line is Ethanol, red line is Acetone and purple line is Formaldehyde, which is the same as the ones in charts below. In Chart 6, Rs represents the resistance value under 50ppm ethanol and various temperatures / humidities; Rs0 represents the resistance value under 50ppm ethanol, 20 ℃ and 55% RH.

pir

The output voltage in Chart 7 is the voltage across the load resistance (RL) of the sensor in series. The test in the figure is completed under standard test conditions, with a test gas of 50 ppm ethanol. The output voltage in Chart 8 is the voltage across the load resistance (RL) of the sensor in series. All tests in the figure are completed under standard test conditions.

pir

In Chart 9, Rs represents the resistance of the sensor in different concentrations of gas Value; R0 represents the resistance value of the sensor in clean air. All tests in the picture are completed under standard test conditions. The black line is for CO, red one is CH4, Purple is for H2 and pink one is Air.In Chart 10 , Rs represents the temperature at 150ppmCO and various temperatures / humidities. Resistance value; Rs0 means resistance value under 150ppmCO, 20 ℃, 55% RH.

pir

The voltage in Chart 11 is the voltage across the load resistance (RL) of the sensor in series. The test in the picture is completed under standard test conditions, test gas 150ppmCO. The output voltage in Chart 12 is the voltage across the load resistance (RL) of the sensor in series. All tests in the picture are completed under standard test conditions.

Platform Supported

ArduinoRaspberry Pi

pir

pir

Schematic Online Viewer

Resources

Tech Support

Please submit any technical issue into our forum.

Upgradable to Industrial Sensors

With the SenseCAP S2110 controller and S2100 data logger, you can easily turn the Grove into a LoRaWAN® sensor. Seeed not only helps you with prototyping but also offers you the possibility to expand your project with the SenseCAP series of robust industrial sensors.

The IP66 housing, Bluetooth configuration, compatibility with the global LoRaWAN® network, built-in 19 Ah battery, and powerful support from APP make the SenseCAP S210x the best choice for industrial applications. The series includes sensors for soil moisture, air temperature and humidity, light intensity, CO2, EC, and an 8-in-1 weather station. Try the latest SenseCAP S210x for your next successful industrial project.


MPN
:
101020820