Product Overview:
The Fibaro Smoke Sensor is a universal, optical Z-Wave smoke detector. Fire alarm is signaled by sound, visual indicator blinking and by sending Z-Wave control commands.
The optical sensor detects smoke at an early stage of fire, often before flames appear and temperature starts to rise significantly. Moreover the device has a built-in temperature sensor, which is programmable indicator of exceeding set temperature level.
The Fibaro Smoke Sensor is designed to be placed on a wall or ceiling. Visual indicator signals fire, operating mode and is used to see if device is within the Z-Wave network. The smoke sensor is designed to operate in confined spaces, under normal conditions (lacking smoke, dust, condensed water vapor).
Product Highlights:
• Compatible with any Z-Wave Controller
• Battery powered
• 3 levels of sensors sensitivity compliant with EN 14604:2005
• Built-in enclosure opening detector
• Dedicated safety mechanism which prevents closing the enclosure without the battery installed
• Alarm signaled by a loud sound, visual indicator and Z-Wave control command
• Additional function of informing about rapid temperature rise by exceeding programmed temperature threshold
• Efficiency test performed automatically every 10 seconds to detect possible malfunction
• Self-test functionality which may be performed manually to test Fibaro Smoke Sensor’s operation
• Built-in “black box” to report and record smoke and temperature readouts in its internal memory
• Built-in Z-Wave range tester
• Wireless software update feature
• Z-Wave Plus compatible
Technical Data:
• Battery Type: CR123A 3.0V DC (battery included)
• Compliance with: LVD 2006/95/EC, EMC 2004/108/EC, R&TTE 1999/5/EC, RoHS 2011/65/EU, EN 14604:2005
• Radio protocol: Z - Wave Plus
• Radio frequency: 868.42 MHz or 869.85 MHz EU; 908.4 MHz or 916 MHz US; 921.4 MHz or 919.8 MHz ANZ; 869 MHz RU;
• Range: up to 50m outdoors; up to 40m indoors (depending on terrain and building structure)
• Operational Temperature: 0oC - 55oC
• Operational Humidity: 0% - 93%
• Measured Temperature Range: -20oC to 100oC
• Smoke sensitivity: 1st level – 1.20 +/- 0.5% obs/ft; 2nd level – 1.80 +/- 0.5% obs/ft; 3rd level – 2.80 +/- 0.5% obs/ft
• Sound pressure level: 85dB / 3m
• Temperature Measuring Accuracy: 0.5oC (within 0oC - 55oC range)
• Dimensions (Diameter x Height): 65mm x 28mm