4 CH 10A Relay Module: Main Function | Statistical functions for running time of Channel | Channel status response | On/off status can be set when Power-Down or Power up | Timer Function | Scene Control | Threshold Function | Curtain Control function | Logic Function: And, Or, Xor, Gate | HeatingFunction: PWM control output
Leading edge and Trailing Edge Technology Dimmers complying with European safety standards and KNX association protocol.TrailingEdge Technology Dimmers Short circuit protection, over load protection,over Heat protection
1-Five channel 10A relay outputs 2-Two channel 0-10V DC outputs 3-Fan speed: High, Medium,Low 4-HVAC working mode: Heating, Cooling 5-HVAC operation mode: Standby mode, Comfort mode, Night mode, Frost protection 6-Fan speed and Valve status report 7-Seven local temperature sampling 8-BUS temperature sampling 9-Local temperature report 10-Seven channel floor heating outputs 11-Five control mode each floor heating channel 12-Seven channel output independently 13-Channel statistics total ON time 14-Channel state response 15-Channel state after bus voltage failure and recovery
24 Zone Dry Contact Module, it includes a 24 channel signal input, Dry contact type can be set Mechanical switch or Electronic switch.
8 CH 16A Relay Module: Main Function | Statistical functions for running time of Channel | Channel status response 1-On/off status can be set when Power-Down or Power up | Timer Function | Scene Control | Threshold Function | Curtain Control function | Logic Function: And, Or, Xor, Gate | Heating Function: PWM control output
1-Blinds operation mode 2-Curtain operation mode 3-Manual operation 4-Priority setup 5-Status can be set when Power-Down or Power up 6-Forced position operation 7-Limit position control 8-Status response for position 9-Status for operation 10-Scene control 11-Safety control 12-Automatic control
NEW Generation Smart DLP wall switch Panel EU, 3 pages For Lighting Control , Curtain Control, one page for floor heating Control, one page for AC control,customize user-friendly graphic, etc. option built-in mini infrared receiver.
8 CH 10A Relay Module: Main Function | Statistical functions for running time of Channel | Channel status response | 1-On/off status can be set when Power-Down or Power up | Timer Function | Scene Control | Threshold Function | Curtain Control function | Logic Function: And, Or, Xor, Gate | HeatingFunction: PWM control output