Product Description

The HDL KNX M/S04 supports 4 Dry Contact input channels, coupled with a temperature sensor, and can output 4 dimming channels or provide LED status indication. The module is able to support three work modes that enable a diverse range of targets to be controlled.

1. Triple working modes

Three work modes are available on the HDL KNX M/S04, they are sensor control, logic control, and dimming control. Below a brief explanation of these modes are given:

  • Sensor control mode enables 4 dry contact channels, or 4 temperature channels, to connect to other devices and control them. 4 channels of LED indicators outputs show the status.
  • Logic control mode enables 4 logic input channels with AND, OR & NOT logic relations to control various targets. LED indicators outputs show the status of the 4 channels.
  • Dimming control mode enables the manual input of 4 channels and 4 dimming channels output. These channels work with a 0-10V dimmer to control various lighting devices.
2. Dimming

This multifunctional switch also supports dimming, and can increase or decrease the light intensity in a variety of situations. This feature is of great benefit as it is able to create different lighting atmospheres via the level of illumination.

3. Multiple control targets

With a single HDL KNX M/S04 module numerous devices and modules can be controlled. Devices which are commonly integrated with this module are switch controllers; switch/dimming controllers, PWM heating controllers, shutter controllers, flexible controllers, scene controllers, sequence controllers, percentage controllers, threshold controllers, string controllers, forced controllers, counter controllers, and combination controllers.


  • With dry contact input and temperature sensor input
  • 0-10V dimmer to control 0-10V devices, likes LED lights
  • LED output(0-2V) indicator
  • Can send the variety control telegram value via KNX .
  • The functions include Switch controller, Switch/Dimming controller, Shutter controller, Flexible controller, Scene controller, Sequence controller, Percentage controller, Threshold controller, String controller, Forced controller, Counter controller, Combination controller, LED status indication
  • Three work modes:
    -Sensors controller (Dry contact sensor, Temperature sensor)
    -Logic controller
    -Dimming controller(0-10V)

Datasheet KNX Dry Contact Sensor 4CH


Electrical Parameters:

-Working Voltage: 21-30 V DC
-Communication: KNX/EIB
-Dynamic Current: <25mA
-Static Current: <5mA
-Output Voltage: 0-10V DC
-DC 0-10V Output Current: 3mA
-KNX Terminals: KNX Bus Terminal– (Red /Black)0.6-0.8mm Diameter Single Core
-Temperature sensor: TTS/APR 1.0 (HDL type)
-Input Sensor: Switch/Temperature sensor

Approved:

-CE, RoHS
-KNX

Product Information:

-Dimensions: 50x50x16(mm)
-Housing material: flame retardant ABS