No items found matching the search criteria
Leading edge and Trailing Edge Technology Dimmers complying with European safety standards and KNX association protocol.Trailing Edge Technology Dimmers Short circuit protection, over load protection,over Heat protection
16CH 10A Relay Module: Main Function | Statistical functions for running time of Channel | Channel status response 1-On/off status can be set when Power-Down or Power up | Timer Function | Scene Control | Threshold Function | Curtain Control function | Logic Function: And, Or, Xor, Gate | HeatingFunction: PWM control output
DMX Recorder with KNX association protocol. Make record and play back DMX program from the KNX software or KNX wall panels. recording time up to 4 hours;,supports the setting and play back of the DMX scenes.
12CH 16A Relay Module: Main Function | Statistical functions for running time of Channel | Channel status response 1-On/off status can be set when Power-Down or Powerup | Timer Function | Scene Control | Threshold Function | CurtainControl function | Logic Function: And, Or, Xor, Gate | Heating Function: PWM control output
Leading edge and Trailing Edge Technology Dimmers complying with European safety standards and KNX association protocol.Trailing Edge Technology Dimmers Short circuit protection, over load protection,over Heat protection.
Edge Technology Dimmers complying with European safety standards and KNX association protocol.Trailing Edge Technology Dimmers Short circuit protection, over load protection,over Heat protection.
16CH 16A Relay Module: Main Function | Statistical functions for running time of Channel | Channel status response 1-On/off status can be set when Power-Down or Power up | Timer Function | Scene Control | Threshold Function | Curtain Control function | Logic Function: And, Or, Xor, Gate | HeatingFunction: PWM control output
HDL KNX Line Coupler, DIN-Rail Mount, to be used as coupler and Repeater(to amplify the signal), if as a line coupler, it can be linked with other line or backbone line, a separate power supply include a choke is required for each new line and each line will be electrically isolated, the line coupler can filter telegrams and permit pass or black them to other adjacent line.
HDL KNX IP Rounter, It can be used as line‐ or backbone coupler and provides a data connection between the upper KNX net/IP line (main line or backbone) and the lower TP KNX bus line (sub line). It also provides with the tunnelling protocol a connection point for ETS to enable commissioning and monitoring.