NSTALLATION
Install to a 86*86 box, power by 220V AC
Power off
Before you install, must cut off the power
INSTALL STEPS
1.Connect each wiring
2.Connect the steel to the 86 box
3.Buckle up the Power box and Panel
OTHER OPERATION
a. External & Internal Temp Check: Long press the" M"and"^"to switch the internal temp or the external temp.
b. Temp Protection Warning: When the temp is higher or lower the protection value,"fire"will flash,the valve will auto close or open, and adjust the temp to 2℃ higher or 2℃ lower of the protection value,"fire"will stop flash and the protection mode cancel.
c. ERR Exception:When the"ERR" light up, it means the sensor mode was wrong or the sensor was broken. And the temp value in the screen will show "--".
d.There have the Anti-locking Function.
e. Check the MAC Address: When the thermostat is power off, and long press the"^"and ">",enter the checking mode, and press"^"or">"to select the address.
ADVANCED SETTINGS
When the thermostat is power on,long press the"^"and ">"(5s) , press"M"select the setting item, and press"^"or">" to select .
1.Type:00: Internal 01: External 02: Internal&External. Default is 00
2 .High temp protection:
35~95℃, Default Is 95℃,"--" Cancel the Protection
3.Low Temp Protection:0~10℃,Default is 5℃,"--"Cancel the Protection
4.Swing: 0-9 ℃,Default 2 ℃ 5.Temperature calibration:ADJ:-9℃~+9℃,Default is 0℃
6.Highest target temp:35~90℃,Default is 35℃
7.Lowest target temp:0~30℃,Default is 5℃