Superior Waterproof Protection Combined with Versatile Functions
IP67 waterproof and dust-tight protection
The IC-F3032T/S series provides outstanding protection against water and dust equivalent to IP67. The IC-F3032T/S series can withstand 1m depth of water for 30 minutes and its dust-tight construction that prevents the ingress of powder dust, sand, mud and other objects.
Longer operating time
The supplied waterproof Li-Ion battery pack, BP-232WP (7.4V, 2300mAh (typ.)), provides 17.5 hours* of operating time. The battery has been designed for reliability in extremely cold environments.
*Tx:Rx:Standby=5:5:90. Power save function ON.
Selective calling, quiet stand-by and more
The IC-F3032T/S series has built-in 2-Tone, 5-Tone, CTCSS and DTCS signaling capabilities for group communication or selective calling. When a matched 2-Tone/5-Tone is received, the following actions are programmable for each code.
- Answer back calls
- Beep sounds
- Bell icon
- Radio stun/kill/revive
- Auto TX
- Scan
MDC 1200 compatible
The following selective calling and ANI features are programmable with the built-in MDC signaling.
- PTT ID
- Emergency (No ACK transmission)
- Radio check (RX only)
- Stun/Revive (RX only)
Emergency function
A red button on the top panel can be used as an emergency button and can be used to transmit an emergency signal. Man down (optional UT-124R required) and lone worker functions can also be used for the emergency function trigger.
Scan features
Priority scan allows you to monitor one or two priority channels while scanning other channels. The mode dependent scan automatically changes the scanning list following the operating channel. The Tx channel and talk back functions allow you to make a quick response while scanning.
Internal option units available
The IC-F3032T/S series has an internal socket for a variety of option units including voice scrambler, DTMF decoder or man down unit.
Other features
- Up to 128 memory channel with 8 zones
- 8-character alphanumeric LCD
- 8 DTMF autodial memories
- Optional HM-168LWP, waterproof speaker-mic
- BIIS PTT ID transmission
- Low battery alert
- 2-step power save
- PC programmable
- Time out timer
- Talk around function
- Surveillance function
General
IC-F3032T/S | IC-F4032T/S | |||
---|---|---|---|---|
Frequency coverage (Varies according to version) | 136–174MHz | 400–470MHz | ||
Number of channels | 128 channels/8 zones | |||
Channel spacing (Varies according to version) | 25/20/12.5 kHz | |||
Type of emission | 16K0F3E/14K0F3E/8K50F3E | |||
Current drain | Tx High | 1.5A (at 5W) | 1.6A (at 4W) | |
Rx | Stand-by | 75mA | ||
Max. audio | 250mA | 300mA | ||
Dimensions (projections not included; W×H×D) | 53×120×37 mm (With BP-232WP) | |||
Weight (approx.) | 310g (With BP-232WP) |
Transmitter
IC-F3032T/S | IC-F4032T/S | |
---|---|---|
RF output power (at 7.2V DC) | 5W, 2W, 1W (Hi, L2, L1) | 4W, 2W, 1W (Hi, L2, L1) |
Spurious emissions | 0.25μW (≤ 1GHz), 1.0μW (> 1GHz) | |
Frequency stability | ±2.5ppm | |
Audio harmonic distortion | 3% typ. (AF 1kHz 40% deviation) |
Receiver
IC-F3032T/S | IC-F4032T/S | |
---|---|---|
Sensitivity at 20dB SINAD | –4dBμV typ. emf | |
Adjacent channel selectivity (W/M/N) | 75/75/65dB typ. | 75/73/65dB typ. |
Spurious response rejection | 70dB min. | |
Intermodulation rejection | 67dB typ. | |
AF output power (at 5% distortion with an 8Ω load) | 500mW typ. |
FUNCTION COMPARISON AND INTERNAL UNIT OPTIONS
IC-F3032T/S IC-F4032T/S | ||
---|---|---|
Number of option slots | 1 | |
CTCSS/ DTCS | encoder | Available |
decoder | Available | |
2-Tone | encoder | Available |
decoder | Available | |
5-Tone | encoder | Available |
decoder | Available | |
DTMF autodial | Available | |
DTMF decoder | - | |
Voice Scrambler | Inversion | - |
Non-rolling | UT-109R | |
Rolling | UT-110R | |
BllS 1200 | PTT ID only | |
MPT 1327 | - | |
LTR™ trunking | - | |
Man Down function | UT-124R | |
Intrinsically safe | - |
Applicable U.S. Military Specifications
Icom makes rugged products that have been tested to and passed the following MIL-STD requirements and strict environmental standards.
Standard | MIL-810 F Method, Proc. |
---|---|
Low Pressure Storage | 500.5 I |
Low Pressure Operation | 500.5 II |
High Temperature Storage | 501.5 I |
High Temperature Operation | 501.5 II |
Low Temperature Storage | 502.5 I |
Low Temperature Operation | 502.5 II |
Temperature Shock | 503.5 I-C |
Solar Radiation | 505.5 I |
Rain Blowing | 506.5 I |
Rain Drip | 506.5 III |
Humidity Induced | 507.5 II |
Salt Fog | 509.5 |
Dust Blowing | 510.5 I |
Immersion | 512.5 I |
Vibration | 514.6 I |
Shock Functional | 516.6 I |
Shock Transit Drop | 516.6 IV |
Also meets equivalent MIL-STD-810 -C, -D, -E and -F.
Ingress Protection Standard (IC-F3032T/S/F4032T/S, BP-232WP & HM-168LWP) | |
---|---|
Dust & Water | IP67 (Dust-tight and waterproof protection) |